展开
Home   Email   Contact Us   中文
Hot Online: +86-13713904196
     HOME        ABOUT US        NEWS        PRODUCTS        Our Clients        SERVICES        FEEDBACK        CONTACT US
--UV Light Sources --Lumen Dynamics S1000-IB with 806-00013 High Power Fiber Light Guide
Fusion Splicer & Accessories
Fujikura
Furukawa Fitel
Sumitomo
Heater Unit
Battery & AC Adapter
Fiber Holder & Clamp
Electrodes
Splicer Part & Accessories
Splicer Keypad
INNO
Ericsson
GREENLEE
ILSINTECH
Signal Fire
Clean Produce
Fiber Cleaver & Stripper
Fiber Cleaver
Fiber Stripper
Blade
UV Curing System
UV Light Sources
UV Bulb / Lamp
Light Guides
OTDRs
Agilent HP
Anristu
EXFO
VEEX
AFL Noyes
Viavi JDSU Acterna
Yokogawa ANDO
LCD & Touch Screen
Others OTDR
Optical Power Meter
Handheld Power Meter
Power Sensor & Optical Head
Connector Adapter
Optical Laser Source
Optical Attenuator
Fiber Inspection Scope
EXFO
VIAVI/JDSU
NIKON
Communications Signal Analyzers
Manual Linear Stages
Optical Spectrum Analyzer
Visual Fault Locator
Cable/Fault Locators
Portable Scanner
Home UV Curing System >> UV Light Sources >> Lumen Dynamics S1000-IB with 806-00013 High Power Fiber Light Guide
UV Curing System
Lumen Dynamics S1000-IB with 806-00013 High Power Fiber Light Guide
Manufacturer:
  Lumen Dynamics
Model:
  S1000-IB
Condition:
  Used
Availability:
  1 unit
Price:
  $2,000.00
Qty:
Description:
98% new. Including:S1000-IB with 320-500nm filter,New 012-60850 lamp, 806-00013 fiber light guide, UV Glasses,Foot pedal,Power cord, manual, 90 days warranty.

   Feature
THE OMNICURE® SERIES 1000 PROVIDES EXCELLENT VERSATALITY IN A COST EFFECTIVE SYSTEM
● 100W lamp with up to 18W/cm2 of output
● Intelli-Lamp® technology to cool and monitor the lamp for extended lamp
life (typically 2000 hours) and optimize performance
● Automatic lamp striking with hot strike prevention that will protect lamp life
● Adjustable light output in 1% increments for precise control
● Selectable bandpass filters to customize light wavelengths for specific
applications
● Easy to use finger touch controls with LED display

THE OMNICURE® ADVANTAGE IN SPOT CURING SYSTEMS
The OmniCure® Series 1000, the first model in the OmniCure® Platform, provides excellent versatility in a cost effective system. Ideal for manual applications, this system contains many features previously found only in higher priced curing systems.

Easy to Use
Finger touch controls, a bright orange LED display,process indicators and automatic lamp striking make the OmniCure® Series 1000 simple to use. New snap-in lamp insertion and low noise fan improves ongoing operation.
Intelligent
The OmniCure® Series 1000 includes many built-in features such as: an adjustable iris; patented Intelli-Lamp® technology; bandpass filters; process alarms;and, password protection which are normally found only in higher priced curing systems.
Versatile
The OmniCure® Series 1000 includes a powerful100W lamp providing high intensity curing and over
2000 hours of lamp life. The broad spectral output makes it ideal for a wide range of applications, while the adjustable iris and selectable bandpass filters allow you to control the light for your specific application.
Adjustable Iris
The adjustable iris allows you to select very precise irradiance levels for your curing application. The iris setting is adjustable in 1% increments with a very linear relationship between the iris position and the output irradiance.
Radiometer Control
For even greater control, combine your OmniCure® Series 1000 with the R2000 Radiometer to adjust the output to specific irradiance values.

FEATURES:
BENEFITS:
100W lamp up to 18W/cm2 of output
Versatility: Delivers the intensity required for a broad range of applications; ideal for use with multi-legged light guides
Long lamp life - 2000 hours (typical)
Lower operating costs
Iris adjustments in 1% increments
Select the specific output intensity required
Advanced shutter/iris wheel
Tested to over 6 million activations for increased reliability
Intelli-Lamp® technology
Maintains optimum operating conditions, stable lamp output,longer lamp life, accumulated lamp hours
Finger touch control panel with LED display
Easy to use
Selectable bandpass filters
Customize the light wavelengths for your application
Shutter, lamp and light guide alarms
Confirms process: ensures repeatability and quality control
Hot strike prevention
Protects lamp life
Password protection
Protects settings for ensured repeatability
Foot pedal (standard)
Convenient hands free operation
Low-noise fan
Quiet operation in the workplace
CE marked; certified to IEC, Canadian and US standards
Ready for use worldwide
Small footprint
Ideal for bench top use and small workstations
   Details

 

 

 

EXPANDING YOUR OPTIONS
Light Delivery
The OmniCure® Series 1000 is ideal for use with multi-legged High Power Fiber Light Guides to cure multiple sites with a single light source. EXFO also offers single-legged, liquid-filled or Quartz fiber light guides to suit most customer needs. Our full line of optical accessories will meet virtually any assembly challenge. EXFO welcomes custom requests for unique light delivery requirements.
Flexible Spectral Output
The broad spectral output makes the OmniCure® Series 1000 ideal for a wide range of applications. Selectable bandpass filters allow you to customize the light for your specific application.
Filter Typical Irradiance Output*
320- 500nm 18,500mW/cm2
320-390nm 8,500mW/cm2
365nm 5,300mW/cm2
400-500nm 6,500mW/cm2
250-450nm** 20,750mW/cm2
250-600nm** 24,750mW/cm2
* Measurements taken with a scanning radiometer: calibration traceable to NIST
** Blank Filter; must use fiber or extended range light guide
SPECIFICATIONS
DESCRIPTION
Lamp
High Pressure 100 Watt Mercury Vapor Short Arc
Lamp Life
2000 hours (typical)
Available Filters
Standard: 320-500nm
Optional: 250-450nm*, 365nm, 320-390nm, 400-500nm, 250-600nm*
Panel Controls
Power On/Off, Display Mode, Adjust UP/DOWN, START/STOP, lock/unlock
Panel Displays
Accumulated Lamp Usage, Exposure Time (0.2 – 999.9sec), iris setting (0–100%) lamp on, shutter open, light guide inserted, shutter/lamp error, lamp warm-up
Warm-up Period
90 seconds (typical)
Power In
100-120VAC / 200-240VAC, 50/60Hz
Power Supply
High efficiency, switch mode, line isolated
GENERAL SPECIFICATIONS
Dimensions (LxWxH)
13.3” x 7.1” x 7.9” / 33.8cm x 18.0cm x 20.1cm
Weight
9.9lbs (4.5kg)
Includes
Lamp Module, Selected Filter (installed), Protective Eyewear, Grounded and Shielded Power Cord, Foot Pedal, Manual
* Blank Filter; must be used with fiber or extended range light guide
Home      About Us      News Center      Products      Services      Feedback      Contact Us     
Copyright © 2006-2020 Optics Equipment All Rights Reserved   Designed:chinweb.net